file://localhost
LIGO Production Large Actuator Test Report |
Actuator Serial #: L023
Operator Name: Smith, Lane
Date: 8/12/2009 Time: 9:26 AM
Actuator Coil Resistance: 6.42 Ohms, PASS
Ambient Temperature: 68.8 F
Hi Pot Test Results: 1000 MOhms, PASS
X Travel Limit (inches): 0.518
Y Travel Limit (inches): 0.205
Z Travel Limit (inches): 0.478
|
X Position (in) |
Y Position (in) |
Z Position (in) |
Current (A) |
Force (lbs) |
Force Constant (lbs/A) |
PASS/FAIL |
Center |
0.000 |
0.000 |
0.000 |
2.150 |
20.232 |
9.408 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
2.434 |
19.844 |
8.153 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
2.362 |
19.821 |
8.393 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
2.342 |
19.827 |
8.465 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
2.485 |
20.035 |
8.063 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
2.398 |
20.104 |
8.382 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
2.317 |
19.895 |
8.586 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
2.386 |
19.919 |
8.349 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
2.356 |
20.162 |
8.558 |
PASS |
Center |
0.000 |
0.000 |
0.000 |
-2.112 |
-20.252 |
9.591 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
-2.361 |
-20.116 |
8.521 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
-2.297 |
-20.218 |
8.801 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
-2.314 |
-20.019 |
8.650 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
-2.314 |
-19.874 |
8.590 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
-2.520 |
-19.928 |
7.906 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
-2.475 |
-19.836 |
8.016 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
-2.377 |
-19.891 |
8.367 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
-2.457 |
-19.807 |
8.061 |
PASS |
QNA-TSG
1901 South Harbor City Blvd
Suite 700
Melbourne, FL 32901
Contact: Scott Stewart
scott.stewart@plansys.com
321-768-6500 x11
© 2009 QinetiQ North America, Technology Solutions Group |