file://localhost
LIGO Production Large Actuator Test Report |
Actuator Serial #: L024
Operator Name: Smith, Lane
Date: 8/12/2009 Time: 7:43 AM
Actuator Coil Resistance: 6.41 Ohms, PASS
Ambient Temperature: 68.9 F
Hi Pot Test Results: 1000 MOhms, PASS
X Travel Limit (inches): 0.516
Y Travel Limit (inches): 0.215
Z Travel Limit (inches): 0.479
|
X Position (in) |
Y Position (in) |
Z Position (in) |
Current (A) |
Force (lbs) |
Force Constant (lbs/A) |
PASS/FAIL |
Center |
0.000 |
0.000 |
0.000 |
2.159 |
20.130 |
9.322 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
2.392 |
19.937 |
8.334 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
2.372 |
20.286 |
8.550 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
2.509 |
19.888 |
7.928 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
2.417 |
20.234 |
8.371 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
2.391 |
20.207 |
8.451 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
2.354 |
20.085 |
8.533 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
2.458 |
20.107 |
8.181 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
2.416 |
20.253 |
8.383 |
PASS |
Center |
0.000 |
0.000 |
0.000 |
-2.130 |
-20.247 |
9.504 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
-2.317 |
-20.138 |
8.690 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
-2.268 |
-20.055 |
8.842 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
-2.294 |
-20.096 |
8.759 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
-2.311 |
-20.186 |
8.736 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
-2.512 |
-19.814 |
7.889 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
-2.470 |
-19.939 |
8.074 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
-2.370 |
-19.921 |
8.405 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
-2.426 |
-20.084 |
8.279 |
PASS |
QNA-TSG
1901 South Harbor City Blvd
Suite 700
Melbourne, FL 32901
Contact: Scott Stewart
scott.stewart@plansys.com
321-768-6500 x11