file://localhost
LIGO Production Large Actuator Test Report |
Actuator Serial #: L001
Operator Name: Smith, Lane
Date: 8/11/2009 Time: 5:37 PM
Actuator Coil Resistance: 6.42 Ohms, PASS
Ambient Temperature: 72.0 F
Hi Pot Test Results: 1000 MOhms, PASS
X Travel Limit (inches): 0.530
Y Travel Limit (inches): 0.196
Z Travel Limit (inches): 0.478
|
X Position (in) |
Y Position (in) |
Z Position (in) |
Current (A) |
Force (lbs) |
Force Constant (lbs/A) |
PASS/FAIL |
Center |
0.000 |
0.000 |
0.000 |
2.102 |
20.162 |
9.591 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
2.480 |
20.268 |
8.172 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
2.304 |
19.829 |
8.608 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
2.352 |
20.188 |
8.583 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
2.403 |
20.008 |
8.328 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
2.290 |
20.010 |
8.738 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
2.328 |
19.871 |
8.534 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
2.301 |
19.888 |
8.644 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
2.288 |
20.068 |
8.772 |
PASS |
Center |
0.000 |
0.000 |
0.000 |
-2.158 |
-20.320 |
9.414 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
-2.368 |
-20.062 |
8.472 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
-2.292 |
-19.953 |
8.706 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
-2.274 |
-19.998 |
8.792 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
-2.336 |
-20.096 |
8.604 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
-2.587 |
-19.855 |
7.675 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
-2.641 |
-19.905 |
7.537 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
-2.390 |
-19.943 |
8.343 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
-2.546 |
-20.007 |
7.858 |
PASS |
QNA-TSG
1901 South Harbor City Blvd
Suite 700
Melbourne, FL 32901
Contact: Scott Stewart
scott.stewart@plansys.com
321-768-6500 x11